Stator cooling water is one of the most critical systems in a power generating plant. The copper stator bars are cooled in this closed loop system to prevent overheating and reduced generator performance.
A mixed bed ion exchange polisher continuously treats the recycling water to remove ionic contaminants while providing some filtration of particulates, generally copper oxides.Graver Technologies has the optimum mixed bed product, Gravex GC-3-1 SC, for your stator cooling system.
Features
- Premium grade mixed bed ion exchange polishing resin
- High capacity strong acid cation and strong base anion components for longest possible run
- Only mixed bed product that meets General Electric’s stringent requirements for stator cooling mixed beds, GE spec A50A306, Rev. S-8
- Specially packaged in durable polyethylene-lined one cubic foot fiber drums
Properties and specifications
Resin Type | Strongly Acidic Cation Exchange Resin Strongly Basic Anion Exchange Resin |
Functionality | Sulfonic Acid Quaternary Ammonium |
Matrix | Styrene-Divinylbenzene |
Cation: Anion Ratio | 1:1 Equivalents |
Total Exchange Capacity | 1.90 meq/mL (Cation H Form) (min) 1.25 meq/mL (Anion OH Form) (min) |
Percent of Sites | 98% Hydrogen (min) 95% Hydroxide (min) |
Water Retention Capacity | 45 – 51% (Cation H Form) 42 – 49% (Anion Cl Form) |
Whole Bead | 99.5% (min) |